Skip to Content
Skip to content
Engineering Guide

Cabling and EMC in Servo Systems: Rules That Work in the Field

Separating power from signal, 360° shield bonding, grounding, EtherCAT cabling, moving cables and filters: the source of most unexplained faults.

Scope

This content supports preliminary sizing and architecture decisions; it does not replace the selected product manual or machine risk assessment.

1. Separate power from signal

Motor power cables are a strong noise source because of the drive's fast switching. Run encoder, network, pulse and analog cables in separate ducts; where they must cross, cross at right angles.

  • Avoid long parallel runs

2. Bond the shield over 360°

The motor-cable shield is bonded at the drive and at the motor with a wide-area clamp. A thin pigtail wire largely cancels the shield at high frequency.

  • Paint is not ground; the clamp sits on bare metal

3. Grounding and the mounting plate

Inside the cabinet, drives, filters and shield clamps meet on a common conductive mounting plate. PE connections are short and of generous cross-section.

4. EtherCAT and network cables

Use shielded cable of at least Cat5e for EtherCAT; at most 100 m between two devices. The line runs in a separate duct from power cables and the connectors must be seated firmly. The ETG.1600 installation guideline gives these rules in detail.

5. Moving cables

Cables flexing in a drag chain must be of the flexible type designed for it; a fixed-installation cable breaks inside and first shows up as random encoder errors. Respect the minimum bending radius.

6. EMI filter and line reactor

An EMI filter stops the drive's noise from returning to the mains; a line reactor reduces harmonics and current surges. Both are mounted close to the drive and well grounded.

SymptomLikely causeCheck
Random encoder error Power and encoder in one duct / fatigued cable Cable route, chain-rated cable
EtherCAT working-counter error Shield, connector, line length Per-port error counters
Position drift with pulses Noisy pulse line Differential drive, shield
Creep on analog command Ground difference, shield Differential input, zero offset

Frequently asked questions

Should the shield be bonded at one end or both?

On the motor power cable, at both ends with a wide-area clamp. For low-level analog signals it may be bonded at one end if a ground loop appears.

How long can an EtherCAT cable be?

At most 100 m between two devices.

Technical sources

Sources are publications from standards owners and manufacturers.

  1. EtherCAT Technology Group — ETG.1600 Installation Guideline
  2. EtherCAT Technology Group — EtherCAT technology

Validate the calculation with a product selection

Send the motion profile and supply conditions, and we will check a suitable motor, drive and cable pairing with you.

Selection Guide Ask an Engineer
Start Product Selection Filter, compare, add to basket